dc.contributor.authorSantos, Tânia-
dc.contributor.authorVentura, Tiago-
dc.contributor.authorMateus, Josefina-
dc.contributor.authorCapela, Miguel-
dc.contributor.authorLopes, Maria do Carmo-
dc.date.accessioned2023-03-27T11:34:00Z-
dc.date.available2023-03-27T11:34:00Z-
dc.date.issued2020-07-
dc.identifier.issn1526-9914pt
dc.identifier.issn1526-9914pt
dc.identifier.urihttps://hdl.handle.net/10316/106237-
dc.description.abstractPurpose: Multiple metrics are proposed to characterize and compare the complexity of helical tomotherapy (HT) plans created for different treatment sites. Methods: A cohort composed of 208 HT plans from head and neck (105), prostate (51) and brain (52) tumor sites was considered. For each plan, 14 complexity metrics were calculated. Those metrics evaluate the percentage of leaves with small opening times or approaching the projection duration, the percentage of closed leaves, the amount of tongue‐and‐groove effect, and the overall modulation of the planned sinogram. To enable data visualization, an approach based on principal component analysis was followed to reduce the dataset dimensionality. This allowed the calculation of a global plan complexity score. The correlation between plan complexity and pretreatment verification results using the Spearman’s rank correlation coefficients was investigated. Results: According to the global score, the most complex plans were the head and neck tumor cases, followed by the prostate and brain lesions irradiated with stereotactic technique. For almost all individual metrics, head and neck plans confirmed to be the plans with the highest complexity. Nevertheless, prostate cases had the highest percentage of leaves with an opening time approaching the projection duration, whereas the stereotactic brain plans had the highest percentage of closed leaves per projection. Significant correlations between some of the metrics and the pretreatment verification results were identified for the stereotactic brain group. Conclusions: The proposed metrics and the global score demonstrated to be useful to characterize and quantify the complexity of HT plans of different treatment sites. The reported differences inter‐ and intra‐group may be valuable to guide the planning process aiming at reducing uncertainties and harmonize planning strategies.pt
dc.language.isoengpt
dc.publisherAmerican Institute of Physicspt
dc.relationSFRH/BD/118929/ 2016pt
dc.relationPOCI‐01‐0145‐FEDER‐028030pt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt
dc.subjecthelical tomotherapypt
dc.subjectplan complexitypt
dc.subjectprincipal component analysispt
dc.subjectplan complexity scorept
dc.subject.meshHeadpt
dc.subject.meshHumanspt
dc.subject.meshMalept
dc.subject.meshNeckpt
dc.subject.meshRadiotherapy Dosagept
dc.subject.meshRadiotherapy Planning, Computer-Assistedpt
dc.subject.meshHead and Neck Neoplasmspt
dc.subject.meshRadiotherapy, Intensity-Modulatedpt
dc.titleOn the complexity of helical tomotherapy treatment planspt
dc.typearticle-
degois.publication.firstPage107pt
degois.publication.lastPage118pt
degois.publication.issue7pt
degois.publication.titleJournal of Applied Clinical Medical Physicspt
dc.peerreviewedyespt
dc.identifier.doi10.1002/acm2.12895pt
degois.publication.volume21pt
dc.date.embargo2020-07-01*
uc.date.periodoEmbargo0pt
item.openairetypearticle-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.fulltextCom Texto completo-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.researchunitINESC Coimbra – Institute for Systems Engineering and Computers at Coimbra-
crisitem.author.researchunitINESC Coimbra – Institute for Systems Engineering and Computers at Coimbra-
crisitem.author.orcid0000-0002-5325-3090-
crisitem.author.orcid0000-0003-1562-0387-
crisitem.author.orcid0000-0001-7339-7342-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
On the complexity of helical tomotherapy treatment plans.pdf851.47 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

6
checked on Jun 24, 2024

WEB OF SCIENCETM
Citations

6
checked on Jul 2, 2024

Page view(s)

69
checked on Jul 2, 2024

Download(s)

61
checked on Jul 2, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons