Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/106697
Title: Fully Untethered Battery-free Biomonitoring Electronic Tattoo with Wireless Energy Harvesting
Authors: Alberto, José 
Leal, Cristina 
Fernandes, Cláudio 
Lopes, Pedro A. 
Paisana, Hugo José Antunes 
Almeida, Aníbal T. de 
Tavakoli, Mahmoud 
Issue Date: 26-Mar-2020
Publisher: Springer Nature
Project: “MATIS-Materiais e Tecnologias Industriais Sustentáveis” (ref.: CENTRO-01-0145-FEDER-000014), co-financed by the European Regional Development Fund (FEDER), through the “Programa Operacional Regional do Centro” (CENTRO2020) 
CMU-Portugal project Stretchtronics (Nr. CMUP-ERI/TIC/0021/2014) 
Dermotronic (02/ SAICT/2017 - 31784) 
PAMI (Nr. CENTRO-01-0145-FEDER-022158) 
metadata.degois.publication.title: Scientific Reports
metadata.degois.publication.volume: 10
metadata.degois.publication.issue: 1
Abstract: Bioelectronics stickers that interface the human epidermis and collect electrophysiological data will constitute important tools in the future of healthcare. Rapid progress is enabled by novel fabrication methods for adhesive electronics patches that are soft, stretchable and conform to the human skin. Yet, the ultimate functionality of such systems still depends on rigid components such as silicon chips and the largest rigid component on these systems is usually the battery. In this work, we demonstrate a quickly deployable, untethered, battery-free, ultrathin (~5 μm) passive "electronic tattoo" that interfaces with the human skin for acquisition and transmission of physiological data. We show that the ultrathin film adapts well with the human skin, and allows an excellent signal to noise ratio, better than the gold-standard Ag/AgCl electrodes. To supply the required energy, we rely on a wireless power transfer (WPT) system, using a printed stretchable Ag-In-Ga coil, as well as printed biopotential acquisition electrodes. The tag is interfaced with data acquisition and communication electronics. This constitutes a "data-by-request" system. By approaching the scanning device to the applied tattoo, the patient's electrophysiological data is read and stored to the caregiver device. The WPT device can provide more than 300 mW of measured power if it is transferred over the skin or 100 mW if it is implanted under the skin. As a case study, we transferred this temporary tattoo to the human skin and interfaced it with an electrocardiogram (ECG) device, which could send the volunteer's heartbeat rate in real-time via Bluetooth.
URI: https://hdl.handle.net/10316/106697
ISSN: 2045-2322
DOI: 10.1038/s41598-020-62097-6
Rights: openAccess
Appears in Collections:I&D ISR - Artigos em Revistas Internacionais

Show full item record

SCOPUSTM   
Citations

64
checked on Oct 14, 2024

WEB OF SCIENCETM
Citations

62
checked on Oct 2, 2024

Page view(s)

105
checked on Oct 29, 2024

Download(s)

82
checked on Oct 29, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons