Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/108392
Title: | Towards the Development of a Low-Cost Device for the Detection of Explosives Vapors by Fluorescence Quenching of Conjugated Polymers in Solid Matrices | Authors: | Martelo, Liliana M. Neves, Tiago F. Pimentel das Figueiredo, João Marques, Lino Fedorov, Alexander Charas, Ana Berberan-Santos, Mário N. Burrows, Hugh D. |
Keywords: | conjugated polymers; explosives detection; trace analysis; optical sensor; luminescence sensor | Issue Date: | 3-Nov-2017 | Publisher: | MDPI | Project: | TIRAMISU project. This project funded by the European Community’s Seventh Framework Program (FP7/2007-2013) under grant 284747 SFRH/BPD/121728/2016 UID/QUI/UI0313/2013 UID/EEA/50008/2013 SFRH/BPD/111301/2015 |
metadata.degois.publication.title: | Sensors (Switzerland) | metadata.degois.publication.volume: | 17 | metadata.degois.publication.issue: | 11 | Abstract: | Conjugated polymers (CPs) have proved to be promising chemosensory materials for detecting nitroaromatic explosives vapors, as they quickly convert a chemical interaction into an easily-measured high-sensitivity optical output. The nitroaromatic analytes are strongly electron-deficient, whereas the conjugated polymer sensing materials are electron-rich. As a result, the photoexcitation of the CP is followed by electron transfer to the nitroaromatic analyte, resulting in a quenching of the light-emission from the conjugated polymer. The best CP in our studies was found to be poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-bithiophene] (F8T2). It is photostable, has a good absorption between 400 and 450 nm, and a strong and structured fluorescence around 550 nm. Our studies indicate up to 96% quenching of light-emission, accompanied by a marked decrease in the fluorescence lifetime, upon exposure of the films of F8T2 in ethyl cellulose to nitrobenzene (NB) and 1,3-dinitrobenzene (DNB) vapors at room temperature. The effects of the polymeric matrix, plasticizer, and temperature have been studied, and the morphology of films determined by scanning electron microscopy (SEM) and confocal fluorescence microscopy. We have used ink jet printing to produce sensor films containing both sensor element and a fluorescence reference. In addition, a high dynamic range, intensity-based fluorometer, using a laser diode and a filtered photodiode was developed for use with this system. | URI: | https://hdl.handle.net/10316/108392 | ISSN: | 1424-8220 | DOI: | 10.3390/s17112532 | Rights: | openAccess |
Appears in Collections: | I&D ISR - Artigos em Revistas Internacionais FCTUC Química - Artigos em Revistas Internacionais |
Files in This Item:
Page view(s)
97
checked on Oct 30, 2024
Download(s)
70
checked on Oct 30, 2024
Google ScholarTM
Check
Altmetric
Altmetric
This item is licensed under a Creative Commons License