Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/27828
Title: Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements
Authors: Attar, Aisha 
Ghica, M. Emilia 
Amine, Aziz 
Brett, Christopher M. A. 
Keywords: Amperometric biosensor; Horseradish peroxidase; Poly(neutral red); Cr(III); Cr(VI); Enzyme inhibition
Issue Date: 30-Aug-2014
Publisher: Elsevier
Citation: ATTAR, Aisha [et. al] - Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements. "Journal of Hazardous Materials". ISSN 0304-3894. Vol. 279 (2014) p. 348–355
Project: info:eu-repo/grantAgreement/EC/FP7/230815/EU 
metadata.degois.publication.title: Journal of Hazardous Materials
metadata.degois.publication.volume: 279
Abstract: Amperometric hydrogen peroxide enzyme inhibition biosensors based on horseradish peroxidase (HRP) immobilised on electropolymerised neutral red (NR) or directly on the surface of carbon film electrodes (CFE) have been successfully applied to the determination of toxic Cr(III) and Cr(VI). Parameters influencing the performance of the biosensor including the enzyme immobilisation method, the amount of hydrogen peroxide, applied potential and electrolyte pH were optimised. The inhibition of horseradish peroxidase by the chromium species was studied under the optimised conditions. Results from the quantitative analysis of chromium ions are discussed in terms of detection limit, linear range and sensitivity. The HRP kinetic interactions reveal mixed binding of Cr(III) with I50 = 3.8 μM and inhibition binding constant Ki = 11.3 μM at HRP/PNR/CFE biosensors and uncompetitive binding of Cr(VI) with I50 = 3.9 μM and Ki = 0.78 μM at HRP/CFE biosensors in the presence of H2O2 substrate. Interferences from other heavy metal ions were studied and the inhibition show very good selectivity towards Cr(III) and Cr(VI).
URI: https://hdl.handle.net/10316/27828
ISSN: 0304-3894
DOI: 10.1016/j.jhazmat.2014.07.019
Rights: openAccess
Appears in Collections:FCTUC Química - Artigos em Revistas Internacionais

Files in This Item:
File Description SizeFormat
Poly(neutral red) based hydrogen peroxide biosensor.pdf656.98 kBAdobe PDFView/Open
Show full item record

SCOPUSTM   
Citations

41
checked on May 1, 2023

WEB OF SCIENCETM
Citations 5

44
checked on Aug 2, 2024

Page view(s) 50

480
checked on Oct 29, 2024

Download(s) 50

485
checked on Oct 29, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.