Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/36998
DC FieldValueLanguage
dc.contributor.advisorViegas, Domingos Xavier-
dc.contributor.advisorOliveira, Ricardo Filipe Silva de-
dc.contributor.authorAlves, Daniela Sofia Antunes-
dc.date.accessioned2017-03-08T15:57:33Z-
dc.date.available2017-03-08T15:57:33Z-
dc.date.issued2016-07-
dc.identifier.urihttps://hdl.handle.net/10316/36998-
dc.descriptionDissertação de Mestrado em Engenharia do Ambiente apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.pt
dc.description.abstractOs incêndios na interface urbano-florestal são atualmente uma área de extrema importância e de crescente investigação. No decorrer de trabalhos em áreas rurais, os equipamentos agroflorestais, quando libertam partículas incandescentes, são referenciados como uma das principais fontes de ignição de incêndios florestais. No âmbito da interface urbano-florestal, as consequências da aproximação dos incêndios aos aglomerados populacionais, ou a estruturas críticas, podem ser catastróficas, do ponto de vista de perdas humanas e materiais. Neste trabalho, que pretende ser um contributo para o conhecimento de mecanismos de supressão e contenção do fogo, são objeto de análise três casos de estudo: extintores de água, barreiras de contenção constituídas por material ignífugo e cercas com sistema de aspersão de água, estes dois últimos casos são denominados ao longo do trabalho como cercas periféricas. A água é um agente de supressão extremamente eficiente, devido ao seu elevado calor latente de vaporização absorve uma grande quantidade de energia dificultando a combustão. Por este motivo deve ser promovida a sua utilização em extintores para fogos de classe A direcionando-a em estudos com combustíveis florestais. No presente, o emprego das soluções analisadas é ainda pouco explorado em sistemas que visem a segurança pessoal e a resiliência das infraestruturas suscetíveis de sofrer um impacto negativo quando atingidas pelo fogo. O objetivo deste trabalho é verificar a eficácia de utilização de extintores de água para incêndios de pequena escala, e de cercas periféricas como meio para impedir ou retardar a passagem do fogo. Os ensaios foram realizados no Laboratório de Estudos sobre Incêndios Florestais (LEIF) da Associação para o Desenvolvimento da Aerodinâmica Industrial (ADAI) da Universidade de Coimbra. A fim de ultrapassar as limitações de escala dos ensaios laboratoriais realizaram-se ensaios no campo experimental da Gestosa, na Serra da Lousã.pt
dc.description.abstractFires in the wildland-urban interface are currently an area of extreme importance and increasing research. In the course of work in rural areas agroforestry equipment can release incandescent particles, which are referenced as a major source of ignition. Within the fires in the wildland-urban interface, the consequences of the approaching fire to settlements, or critical structures can be catastrophic both in human and material losses. This work, which is intended as a contribution to the knowledge of suppression and containment of fire mechanisms, for this purpose three case studies are presented: Water extinguishers, containment barriers consisting on flame-retardant material and fences with water sprinkler system, the latter two cases are referred to throughout the work as peripheral fences. Water is an extremely efficient suppressing agent, due to its high latent heat of vaporization absorbs a large quantity of energy hindering the combustion process. Its use in fire extinguishers for Class A fires should be promoted using it in studies with forest fuels. At the present, the study of systems aimed at personal security and resilience of infrastructure susceptible to be negatively impacted, when affected by fire, remains underexplored. The main goal of this study is to verify the use effectiveness of water for extinguishing small fires and peripheral fences in preventing the passage of fire. The tests were performed at the Laboratory for Forest Fire Studies (LEIF) of the Association for the Development of Industrial Aerodynamics (ADAI), Coimbra University. In order to overcome the scale limitations of laboratory, in loco tests were carried out at Gestosa experimental field in the Serra da Lousã.pt
dc.language.isoporpt
dc.rightsopenAccesspt
dc.subjectIncêndios florestaispt
dc.subjectExtintorpt
dc.subjectCombate a incêndiospt
dc.titleEstudo da eficácia de extintores de água e de cercas periféricas para contenção do avanço de uma frente de fogopt
dc.title.alternativeEfficiency of water extinguishers and peripheric and water spraying barriers to contain a fire frontpt
dc.typemasterThesispt
degois.publication.locationCoimbrapt
dc.peerreviewednopor
dc.date.embargo2016-07-01*
dc.subject.fosDomínio/Área Científica::Engenharia e Tecnologia::Engenharia Mecânicapt
thesis.degree.grantor00500::Universidade de Coimbrapt
thesis.degree.nameMestrado em Engenharia do Ambiente (Tecnologia e Gestão do Ambiente)-
uc.rechabilitacaoestrangeiranopt
uc.date.periodoEmbargo0pt
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextCom Texto completo-
item.openairetypemasterThesis-
item.cerifentitytypePublications-
item.languageiso639-1pt-
crisitem.advisor.researchunitLAETA - Associated Laboratory for Energy, Transports and Aeronautics-
crisitem.advisor.orcid0000-0001-6690-035X-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Mecânica - Teses de Mestrado
Show simple item record

Page view(s)

418
checked on Oct 29, 2024

Download(s) 50

1,213
checked on Oct 29, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.