Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/38640
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Mateus, Diogo Manuel Rosa | - |
dc.contributor.advisor | Pereira, Andreia Sofia Carvalho | - |
dc.contributor.author | Goncalves, Ana Margarida Gregorio | - |
dc.date.accessioned | 2017-03-27T10:21:33Z | - |
dc.date.available | 2017-03-27T10:21:33Z | - |
dc.date.issued | 2015-02-16 | - |
dc.identifier.uri | https://hdl.handle.net/10316/38640 | - |
dc.description | Dissertação de Mestrado Integrado em Engenharia Civil apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra. | pt |
dc.description.abstract | As questões de ordem ambiental têm sido cada vez mais motivo de preocupação a nível mundial, por resultarem em alterações climáticas e consequentes problemas ambientais, sociais e económicos. Em Portugal, o setor dos edifícios é responsável por uma percentagem significativa dos consumos energéticos, sendo também um dos principais responsáveis pelas emissões de dióxido de carbono. Desta forma, é dada grande importância às intervenções ao nível dos edifícios, apostando na promoção da eficiência energética e na adoção de medidas legislativas que obriguem ao aumento dessa eficiência. Sabe-se que o desempenho térmico dos edifícios está diretamente relacionado com o comportamento térmico das suas envolventes, sendo determinante o coeficiente de transmissão térmica. É apresentada neste trabalho uma metodologia para a avaliação in situ do desempenho térmico de soluções construtivas, com recurso a um sistema de medição do fluxo de calor e das temperaturas superficiais e ambientes. Concluídas as medições, essa avaliação pode ser feita recorrendo a cálculos e determinando o respetivo coeficiente de transmissão térmica. O objetivo desta determinação consiste na comparação entre os valores medidos in situ com os valores previstos para o edifício na fase de projeto. Os resultados dos ensaios indicam que pode existir convergência entre os valores do coeficiente de transmissão térmica medidos e os valores de projeto. Durante as medições deve ser mantido um diferencial de temperatura significativo entre o interior e o exterior do edifício. Para além disso, a temperatura interior deve ser mantida o mais estável possível e a duração do ensaio não deve ser inferior a 4 dias. Desta forma, o método pode ser usado na avaliação do desempenho energético de edifícios e na deteção de causas de eventuais patologias. | pt |
dc.description.abstract | The environmental issues have been more and more reasons of a world concern, as they result in climate changes and related environmental, social and economic problems. The building sector in Portugal is responsible for a significant percentage of power consumption, being also one of the main responsible for the carbon dioxide emissions. Thus, it is given great importance to the buildings level interventions, focusing in the energy efficiency promotion and in adopting legislative measures mandatory for this efficiency increase. It is known that buildings thermal performance is directly related to the thermal behavior of their surroundings, being determinant the thermal transmittance coefficient. In this paper is presented a methodology for an in situ thermal performance evaluation of constructive solutions, using a heat flux, surface and ambient temperatures measurements system. Collected the measurements, this evaluation can be made using calculations and obtaining the correspondent thermal transmittance coefficient. The target of this determination is to compare the in situ measured values with the building projected values. The test results indicate that there can be a convergence between measured thermal transmittance coefficient values and project values. During the measurement period it should be kept a significant differential temperature from the inside and the outside of the building. Either the inside temperature should be kept as stable as possible and the test time length should not be less than 4 days. This way, the method can be used for the buildings energetic efficiency evaluation and in detection of possible buildings pathologies causes. | pt |
dc.language.iso | por | pt |
dc.rights | openAccess | pt |
dc.subject | Desempenho térmico de edifícios | pt |
dc.title | Avaliação in situ do desempenho térmico de soluções construtivas | pt |
dc.type | masterThesis | pt |
degois.publication.location | Coimbra | pt |
dc.date.embargo | 2015-02-16 | * |
dc.identifier.tid | 201659557 | pt |
thesis.degree.grantor | 00500::Universidade de Coimbra | pt |
thesis.degree.name | Mestrado Integrado em Engenharia Civil | pt |
uc.degree.grantorUnit | 0501 - Faculdade de Ciências e Tecnologia | por |
uc.rechabilitacaoestrangeira | no | pt |
uc.date.periodoEmbargo | 0 | pt |
uc.controloAutoridade | Sim | - |
item.languageiso639-1 | pt | - |
item.fulltext | Com Texto completo | - |
item.grantfulltext | open | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | masterThesis | - |
item.cerifentitytype | Publications | - |
crisitem.advisor.researchunit | Centre for Research in Construction Science | - |
crisitem.advisor.orcid | 0000-0002-9322-6353 | - |
Appears in Collections: | UC - Dissertações de Mestrado FCTUC Eng.Civil - Teses de Mestrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Avaliacao in situ do desempenho termico de solucoes construtivas.pdf | 1.75 MB | Adobe PDF | View/Open |
Page view(s)
184
checked on Nov 6, 2024
Download(s)
332
checked on Nov 6, 2024
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.