Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/4063
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Faia, P. M. | - |
dc.contributor.author | Furtado, C. S. | - |
dc.contributor.author | Ferreira, A. J. | - |
dc.date.accessioned | 2008-09-01T09:58:37Z | - |
dc.date.available | 2008-09-01T09:58:37Z | - |
dc.date.issued | 2005 | en_US |
dc.identifier.citation | Sensors and Actuators B: Chemical. 107:1 (2005) 353-359 | en_US |
dc.identifier.uri | https://hdl.handle.net/10316/4063 | - |
dc.description.abstract | The variation of the electrical signal with humidity in ceramic sensors is originated by the chemical and physical sorptions of water molecules existing in the atmosphere. The aim of the work described in the present paper is to establish an equivalent electrical circuit for the case of two titania thick-film samples. It is shown, at least for the temperature of 23 °C, that the same type of circuit represents adequately these two samples for various relative humidities. Chemisorption and physisorption are responsible for the different charge transport mechanisms - ion hopping, ion diffusion and electrolytic conduction. Complex impedance data were obtained at the temperature of 23 °C and various relative humidities, in the frequency range 0.1 Hz-40 MHz. The best and simpler circuit representation we found, which gives the best fitting for the Cole-Cole and Bode plots, consists of two RC parallel circuits in series with two constant-phase elements (CPEs). The values of the electrical components are tabled and, as an example, the Cole-Cole and Bode plots fitting obtained for one of our samples, the sample B, for 87.5% RH, in the frequency range 0.1 Hz-40 MHz is shown. | en_US |
dc.description.uri | http://www.sciencedirect.com/science/article/B6THH-4DYW4YK-3/1/8a4bd418ee28187eecebe9d1e1d8a6f0 | en_US |
dc.format.mimetype | aplication/PDF | en |
dc.language.iso | eng | eng |
dc.rights | openAccess | eng |
dc.subject | Humidity sensor | en_US |
dc.subject | Titania | en_US |
dc.subject | Thick film | en_US |
dc.subject | Impedance spectroscopy | en_US |
dc.subject | Circuit modelling | en_US |
dc.title | AC impedance spectroscopy: a new equivalent circuit for titania thick film humidity sensors | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1016/j.snb.2004.10.021 | - |
item.grantfulltext | open | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | Com Texto completo | - |
item.openairetype | article | - |
item.cerifentitytype | Publications | - |
item.languageiso639-1 | en | - |
crisitem.author.researchunit | CEMMPRE - Centre for Mechanical Engineering, Materials and Processes | - |
crisitem.author.orcid | 0000-0001-5539-9766 | - |
Appears in Collections: | FCTUC Eng.Electrotécnica - Artigos em Revistas Internacionais |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
filed87759a5aa254223aee87008fc735c17.pdf | 158.09 kB | Adobe PDF | View/Open |
SCOPUSTM
Citations
95
checked on Jun 3, 2024
WEB OF SCIENCETM
Citations
91
checked on Jun 2, 2024
Page view(s)
326
checked on Oct 30, 2024
Download(s) 50
652
checked on Oct 30, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.