Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/4538
Campo DCValorIdioma
dc.contributor.authorRachinhas, P. J. B. M.-
dc.contributor.authorSimões, P. C. P. S.-
dc.contributor.authorLopes, J. A. M.-
dc.contributor.authorDias, T. H. V. T.-
dc.contributor.authorMorgado, R. E.-
dc.contributor.authorSantos, J. M. F. dos-
dc.contributor.authorStauffer, A. D.-
dc.contributor.authorConde, C. A. N.-
dc.date.accessioned2008-09-01T11:08:49Z-
dc.date.available2008-09-01T11:08:49Z-
dc.date.issued2000en_US
dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 441:3 (2000) 468-478en_US
dc.identifier.urihttps://hdl.handle.net/10316/4538-
dc.description.abstractThe application of gas proportional scintillation counters (GPSC) to the detection and identification of conversion electrons in the medium energy range is investigated. Experimental and Monte Carlo results are presented for the response of a xenon GPSC, filled at atmospheric pressure, to the decay of a 109Cd source. This source emits 88.0 keV [gamma]-rays, eL=84.6 keV and eK=62.5 keV conversion electrons, as well as fluorescence X-rays and Auger electrons. Good agreement is found between the measured and the calculated energy spectra. The response to higher-energy electrons is investigated by Monte Carlo simulation, by considering a hypothetical GPSC filled with xenon at 10 atm and doped with the 133mXe metastable isotope. The calculated energy spectra for the absorption of the 133mXe 233.2 keV [gamma]-rays, eK=198.6 keV and eL=228.4 keV conversion electrons, as well as fluorescence X-rays and Auger electrons, are presented and discussed.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6TJM-3YS91CB-J/1/4b48a2a89f10ac68be0e04c4537a9d54en_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectGas scintillation detectorsen_US
dc.subjectConversion electronsen_US
dc.subjectMonte Carlo simulationen_US
dc.subjectDigital pulse processingen_US
dc.titleSimulation and experimental results for the detection of conversion electrons with gas proportional scintillation countersen_US
dc.typearticleen_US
dc.identifier.doi10.1016/S0168-9002(99)00978-X-
item.fulltextCom Texto completo-
item.grantfulltextopen-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.openairetypearticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0002-8841-6523-
Aparece nas coleções:FCTUC Física - Artigos em Revistas Internacionais
Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
file702eece8f63e4928a6b8b5ace0b31803.pdf436.01 kBAdobe PDFVer/Abrir
Mostrar registo em formato simples

Citações SCOPUSTM   

19
Visto em 17/nov/2022

Citações WEB OF SCIENCETM

14
Visto em 2/mai/2023

Visualizações de página 50

562
Visto em 25/set/2024

Downloads 50

497
Visto em 25/set/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.