Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10316/4538
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Rachinhas, P. J. B. M. | - |
dc.contributor.author | Simões, P. C. P. S. | - |
dc.contributor.author | Lopes, J. A. M. | - |
dc.contributor.author | Dias, T. H. V. T. | - |
dc.contributor.author | Morgado, R. E. | - |
dc.contributor.author | Santos, J. M. F. dos | - |
dc.contributor.author | Stauffer, A. D. | - |
dc.contributor.author | Conde, C. A. N. | - |
dc.date.accessioned | 2008-09-01T11:08:49Z | - |
dc.date.available | 2008-09-01T11:08:49Z | - |
dc.date.issued | 2000 | en_US |
dc.identifier.citation | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 441:3 (2000) 468-478 | en_US |
dc.identifier.uri | https://hdl.handle.net/10316/4538 | - |
dc.description.abstract | The application of gas proportional scintillation counters (GPSC) to the detection and identification of conversion electrons in the medium energy range is investigated. Experimental and Monte Carlo results are presented for the response of a xenon GPSC, filled at atmospheric pressure, to the decay of a 109Cd source. This source emits 88.0 keV [gamma]-rays, eL=84.6 keV and eK=62.5 keV conversion electrons, as well as fluorescence X-rays and Auger electrons. Good agreement is found between the measured and the calculated energy spectra. The response to higher-energy electrons is investigated by Monte Carlo simulation, by considering a hypothetical GPSC filled with xenon at 10 atm and doped with the 133mXe metastable isotope. The calculated energy spectra for the absorption of the 133mXe 233.2 keV [gamma]-rays, eK=198.6 keV and eL=228.4 keV conversion electrons, as well as fluorescence X-rays and Auger electrons, are presented and discussed. | en_US |
dc.description.uri | http://www.sciencedirect.com/science/article/B6TJM-3YS91CB-J/1/4b48a2a89f10ac68be0e04c4537a9d54 | en_US |
dc.format.mimetype | aplication/PDF | en |
dc.language.iso | eng | eng |
dc.rights | openAccess | eng |
dc.subject | Gas scintillation detectors | en_US |
dc.subject | Conversion electrons | en_US |
dc.subject | Monte Carlo simulation | en_US |
dc.subject | Digital pulse processing | en_US |
dc.title | Simulation and experimental results for the detection of conversion electrons with gas proportional scintillation counters | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1016/S0168-9002(99)00978-X | - |
item.fulltext | Com Texto completo | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
item.openairetype | article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
crisitem.author.researchunit | LIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics | - |
crisitem.author.parentresearchunit | University of Coimbra | - |
crisitem.author.orcid | 0000-0002-8841-6523 | - |
Aparece nas coleções: | FCTUC Física - Artigos em Revistas Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
file702eece8f63e4928a6b8b5ace0b31803.pdf | 436.01 kB | Adobe PDF | Ver/Abrir |
Citações SCOPUSTM
19
Visto em 17/nov/2022
Citações WEB OF SCIENCETM
14
Visto em 2/mai/2023
Visualizações de página 50
562
Visto em 25/set/2024
Downloads 50
497
Visto em 25/set/2024
Google ScholarTM
Verificar
Altmetric
Altmetric
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.