Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/7939
Title: | Diphasic dialysis extraction technique for clenbuterol determination in bovine retina by gas chromatography-mass spectrometry | Authors: | Ramos, F. Matos, A. Oliveira, A. Silveira, M. I. Noronha da |
Issue Date: | 1999 | Citation: | Chromatographia. 50:1 (1999) 118-120 | Abstract: | Summary A method is described for the extraction of clebuterol from bovine retina samples by diphasic dialysis using gas chromatography—mass spectrometry (GC-MS) as the procedure of determination. Following chemical digestion of retinal tissue in alkaline medium at 80C, clenbuterol is extracted by diphasic dialysis using diethyl ether as solvent at 37C, for 4 h at 150 rpm. Diethyl ether is evaporated to dryness and clenbuterol determined by GC-MS after butylboronic acid (BBA) derivatization. A detection limit of 2.5 ng g-1, repeatability of 9.0% and reproducibility of 22.9%, with recoveries always >86% (n=5), are achieved as validation criteria. | URI: | https://hdl.handle.net/10316/7939 | DOI: | 10.1007/BF02493629 | Rights: | openAccess |
Appears in Collections: | FFUC- Artigos em Revistas Internacionais |