Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/82848
DC FieldValueLanguage
dc.contributor.advisorPaiva, Rui Pedro Pinto de Carvalho e-
dc.contributor.advisorCruz, Tiago José dos Santos Martins da-
dc.contributor.authorFernandes, João Tiago Márcia do Nascimento-
dc.date.accessioned2018-12-22T18:38:05Z-
dc.date.available2018-12-22T18:38:05Z-
dc.date.issued2017-07-07-
dc.date.submitted2019-01-20-
dc.identifier.urihttps://hdl.handle.net/10316/82848-
dc.descriptionDissertação de Mestrado em Engenharia Informática apresentada à Faculdade de Ciências e Tecnologia-
dc.description.abstractEste trabalho pretende explorar diferentes formas de auscultar som pulmonar (por exemplo, tosse e pieiras) usando sistemas embutidos e um microfone eletrónico. Esta abordagem usa dispositivos de baixo custo e os resultados foram comparados com o estado da arte para este tipo de dispositivos, o estetoscópio electrónico Littmann 3200. Várias versões do protótipo foram construídas devido ao ruído que estava presente no som (tornava o som pulmonar praticamente inaudível, o que não permitia que fosse usado para adquirir esses mesmos sons, implicando ter que voltar a pensar numa solução diferente). Foram, também, tentadas usar transmissões sem fios (recorrendo ao Bluetooth e Wi-Fi), mas não foi possível conciliar a transmissão de dados em tempo real com a transmissão sem fios. Após testar o nosso protótipo, obtivemos bons resultados tanto na auscultação da tosse (sensibilidade de 76.97% ± 31.16% e especificidade de 99.83% ± 0.01% contra sensibilidade de 83.90% ± 31.97% e especificidade de 99.97% ± 0.00% no Littmann), como no conforto (média de 9 em 10, o mesmo que no Littmann) e nos custos (41€ contra os 350€ do Littmann). Em contrapartida, o nosso protótipo não durou um dia inteiro ligado (tal como o Littmann) e a qualidade do som foi má (ao passo que a do Littmann foi boa). Apesar de um dos testes conter pieiras, não foi possível concluir nada relativamente a este tipo de som. No final, o nosso protótipo obteve bons resultados, tendo falhado nalguns aspectos que não o tornaram numa construção completamente bem-sucedido.por
dc.description.abstractThis work explored a different way to measure lung sounds (i.e. cough and wheezes) by using embedded systems and an electronic microphone. This approach used low cost devices and the results were compared to a current state of the art device, the Littmann 3200 electronic stethoscope. Several versions of prototypes were built because the sound provided by the circuit was full of noise (it made the pulmonary sound almost inaudible, which did not allow it to be used to acquire lung sounds and, consequently, we needed to think in a different solution). Wireless transmissions (i.e. Bluetooth and Wi-Fi) were intended to be used, but it was not possible to conciliate both real-time data and wireless transmission. After tested the developed prototype, overall we obtained good results either on auscultating cough (sensitivity 76.97% ± 31.16% and specificity 99.83% ± 0.01% versus sensitivity 83.90% ± 31.97% and specificity 99.97% ± 0.00% of the Littmann), on comfort (average of 9 out of 10, same as the Littmann) and costs (41€ versus 350€ of the Littmann). On the other hand, it did not last a full day (neither the Littmann) and the sound quality was bad (the Littmann was good). Although one test contained wheezes, it was not possible to conclude anything related to this adventitious sound. At the end, our prototype had good results, having failed in some aspects that did not make it completely successful.eng
dc.language.isoeng-
dc.rightsopenAccess-
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectPieiraspor
dc.subjectTossepor
dc.subjectSistemas Embutidospor
dc.subjectAquisição de Sons Pulmonares em Tempo Realpor
dc.subjectWheezeseng
dc.subjectCougheng
dc.subjectEmbedded Systemseng
dc.subjectReal-time lung sounds acquisitioneng
dc.titleUsing Low Cost Embedded Systems for Lung Sounds Auscultation and Analysiseng
dc.title.alternativeSistemas Embebidos de Baixo Custo para Aquisição e Análise de Sons Pulmonarespor
dc.typemasterThesis-
degois.publication.locationDEI-FCTUC-
degois.publication.titleUsing Low Cost Embedded Systems for Lung Sounds Auscultation and Analysiseng
dc.peerreviewedyes-
dc.identifier.tid202123723-
thesis.degree.disciplineInformática-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado em Engenharia Informática-
uc.degree.grantorUnitFaculdade de Ciências e Tecnologia - Departamento de Engenharia Informática-
uc.degree.grantorID0500-
uc.contributor.authorFernandes, João Tiago Márcia do Nascimento::0000-0002-2822-1214-
uc.degree.classification17-
uc.degree.presidentejuriHenriques, Jorge Manuel Oliveira-
uc.degree.elementojuriCurado, Marília Pascoal-
uc.degree.elementojuriPaiva, Rui Pedro Pinto de Carvalho e-
uc.contributor.advisorPaiva, Rui Pedro Pinto de Carvalho e::0000-0003-3215-3960-
uc.contributor.advisorCruz, Tiago José dos Santos Martins da::0000-0001-9278-6503-
uc.controloAutoridadeSim-
item.openairetypemasterThesis-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.fulltextCom Texto completo-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.advisor.researchunitCISUC - Centre for Informatics and Systems of the University of Coimbra-
crisitem.advisor.researchunitCISUC - Centre for Informatics and Systems of the University of Coimbra-
crisitem.advisor.parentresearchunitFaculty of Sciences and Technology-
crisitem.advisor.parentresearchunitFaculty of Sciences and Technology-
crisitem.advisor.orcid0000-0003-3215-3960-
crisitem.advisor.orcid0000-0001-9278-6503-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat
thesis-embedded-systems.pdf12.04 MBAdobe PDFView/Open
Show simple item record

Page view(s) 20

641
checked on Jul 3, 2024

Download(s) 50

716
checked on Jul 3, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons