Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/97310
Title: | Caracterização hidrogeoquímica das águas subterrâneas nas regiões do Lubango e Palanca (Humpata) | Authors: | António, Fábio Paulo Lunge | Orientador: | Silva, Maria Manuela da Vinha Guerreiro da Pinto, Marina Marques da Silva Cabral |
Keywords: | águas subterrâneas; contaminação urbana; hidroquímica; Lubango; groundwater; urban contamination; Hydrochemistry; Lubango | Issue Date: | Oct-2014 | metadata.degois.publication.location: | Coimbra | Abstract: | De março a agosto de 2014 realizou-se o trabalho de caraterização hidroquímica
das massas de águas subterrâneas nos Municípios do Lubango (especificamente
nos bairros do Tchioco, Nambambi, Bula Matadi e Lalula e Comandante Cowboy) e
de Humpata na região da Palanca, Província da Huíla, sudoeste de Angola.
Amostraram-se 12 cacimbas (poços) na época chuvosa e quente e na época seca e
fria com o objetivo de avaliar o grau de contaminação das águas subterrâneas. Os
vários bairros onde as águas foram amostradas caraterizam-se pela inexistência ou
insuficiência da rede de distribuição de água potável, de esgotos e recolha de
resíduos urbanos. Os resíduos sólidos existem dispersos em várias lixeiras e os
efluentes domésticos são armazenados em fossas negras, potenciando a
contaminação dos aquíferos subterrâneos.
Os parâmetros físico-químicos foram determinados in situ, com um medidor
multiparâmetros e as espécies químicas foram determinadas com o fotómetro de
bancada. A alcalinidade nunca foi detetada indicado que as águas têm baixa
capacidade de tamponização para mudanças de pH, devido à litologia. O zinco e
manganês nunca foram detetados e o crómio VI apenas foi detetado na época
seca. Fez-se a avaliação da qualidade das águas de acorde com o Decreto lei nº
306/2007 da lei Portuguesa, as linhas orientadoras da WHO (2011) e do Ministry of
the Environment (2011), (Ontario guidelines). As águas não estão contaminadas em
nitrato, fosfato, sulfato em nenhuma época e na generalidade não estão
contaminadas em nitrito com exceção de um poço localizado na região da Palanca
(PA2). Na generalidade também não estão contaminadas em amónia com exceção
de um poço localizado no bairro Comandante Cowboy (CV3). Os teores de ferro e
de cobre das águas amostradas estão, principalmente na época chuvosa, em
alguns poços, acima do valor paramétrico.
Portanto, observou-se contaminação das águas subterrâneas em alguns poços,
provavelmente por atividades antrópicas nomeadamente a disposição não
condicionada de efluentes domésticos. The hydrochemical characterization of groundwater bodies was performed from Mars to August 2014 in the municipalities of Lubango (specifically in the neighborhoods of Tchioco, Nambambi, Bula Matadi e Lalula and Comandante Cowboy) and Humpata, region of Palanca, Huíla Province, southwest of Angola. Sampling and analyses of ground waters were performed in 12 wells, during the rainy, hot season and during the dry, cold season with the objective of assessing the degree of contamination of groundwater. The neighborhoods are characterized by the absence, or insufficiency, of the a distribution network of drinking water, sewerage and waste collection. Solid wastes are dispersed in multiple dumpsters and domestic waste are stored in pits black, potentiating the contamination of underground aquifers. The physical and chemical parameters were determined in situ with a multiparameter sensor and the chemical species were determined with the photometer bench. Alkalinity was never detected, indicated that the waters have low buffer capability to pH changes, due to lithology. Zinc and manganese were not detected and the chromium VI was only detected in the dry season. To assess the water quality the Decree Law nº 306/2007 Portuguese law, the guidelines of the WHO (2011) and the Ministry of the Environment (2011), (Ontario guidelines) were used. The waters are not contaminated in nitrate, phosphate, sulfate and in general are not contaminated in nitrite with the exception of a well located in the region of Palanca (PA2). In general are also not contaminated in ammonia with the exception of a well located in the Comandante Cowboy (CV3) neighborhood. The iron and copper contents of the sampled waters are above the guideline values, especially in the rainy season , in some wells. Therefore some groundwater contamination was observed in some wells, probably by anthropogenic activities namely the domestic effluent dsiposal. |
Description: | Dissertação de Mestrado em Geociências, Ambiente e Ordenamento, apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra. | URI: | https://hdl.handle.net/10316/97310 | Rights: | embargoedAccess |
Appears in Collections: | FCTUC Ciências da Terra - Teses de Mestrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Tese final Fábio António.pdf | 1.86 MB | Adobe PDF | View/Open | |
capa Fábio António.pdf | 187.52 kB | Adobe PDF | View/Open |
Page view(s)
148
checked on Nov 5, 2024
Download(s)
185
checked on Nov 5, 2024
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.