Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/102102
DC FieldValueLanguage
dc.contributor.authorLopes, João-
dc.contributor.authorSimão, Miguel-
dc.contributor.authorMendes, Nuno-
dc.contributor.authorSafeea, Mohammad-
dc.contributor.authorAfonso, José-
dc.contributor.authorNeto, Pedro-
dc.date.accessioned2022-09-26T07:46:00Z-
dc.date.available2022-09-26T07:46:00Z-
dc.date.issued2017-
dc.identifier.issn23519789pt
dc.identifier.urihttps://hdl.handle.net/10316/102102-
dc.description.abstractGesture recognition is more reliable with a proper motion segmentation process. In this context we can distinguish if gesture patterns are static or dynamic. This study proposes a gesture segmentation method to distinguish dynamic from static gestures, using (Inertial Measurement Units) IMU and Electromyography (EMG) sensors. The performance of the sensors, individually as well as their combination, was evaluated by different users. It was concluded that when considering gestures which only contain arm movement, the lowest error obtained was by the IMU. However, as expected, when considering gestures which have only hand motion, the combination of the 2 sensors achieved the best performance. Results of the sensor fusion modality varied greatly depending on user. The application of different filtering method to the EMG data as a solution to the limb position resulted in a significative reduction of the error.pt
dc.language.isoengpt
dc.relationPortugal 2020 project DM4Manufacturing POCI-01-0145-FEDER-016418 by UE/FEDER through the program COMPETE2020pt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt
dc.subjectGesturespt
dc.subjectSegmentationpt
dc.subjectMotionpt
dc.subjectIMUpt
dc.subjectEMGpt
dc.titleHand/arm Gesture Segmentation by Motion Using IMU and EMG Sensingpt
dc.typearticle-
degois.publication.firstPage107pt
degois.publication.lastPage113pt
degois.publication.titleProcedia Manufacturingpt
dc.peerreviewedyespt
dc.identifier.doi10.1016/j.promfg.2017.07.158pt
degois.publication.volume11pt
dc.date.embargo2017-01-01*
uc.date.periodoEmbargo0pt
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextCom Texto completo-
item.openairetypearticle-
item.cerifentitytypePublications-
item.languageiso639-1en-
crisitem.author.researchunitCEMMPRE - Centre for Mechanical Engineering, Materials and Processes-
crisitem.author.orcid0000-0003-1480-976X-
crisitem.author.orcid0000-0003-2177-5078-
Appears in Collections:FCTUC Eng.Mecânica - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
1-s2.0-S2351978917303645-main.pdf646.81 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

23
checked on Nov 4, 2024

WEB OF SCIENCETM
Citations

17
checked on Nov 2, 2024

Page view(s)

117
checked on Oct 29, 2024

Download(s)

70
checked on Oct 29, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons