Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/107983
Título: Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle position
Autor: Duarte, João P. 
Valente-dos-Santos, João 
Coelho-e-Silva, Manuel J. 
Couto, Pedro 
Costa, Daniela 
Martinho, Diogo V. 
Seabra, André
Cyrino, Edilson S.
Conde, Jorge 
Rosado, Joana
Gonçalves, Rui S. 
Data: 2018
Editora: Public Library of Science
Projeto: uid/dtp/04213/2016 
SFRH/BD/101083/2014 
SFRH/BPD/100470/ 2014 
SFRH/BD/121441/ 2016 
Título da revista, periódico, livro ou evento: PLoS ONE
Volume: 13
Número: 8
Resumo: The current study aimed to examine the reliability of the conventional and functional ratios derived from peak torques (PTs) and those obtained from the combination of knee flexors torque at the angle of knee extensors PT. Twenty-six male athletes (mean of 24.0±0.7 years) from different sports completed a test-to-test variation in isokinetic strength (Biodex, System 3) within a period of one week. Anthropometry and body composition assessed by Dual Energy X-ray Absorptiometry were also measured. The proposed isokinetic strength ratio measurements appeared to be highly reliable: conventional ratio at PT angle (intra-class correlation, ICC = 0.98; 95% confidence interval; 95%CI: 0.95 to 0.99); functional extension ratio at PT angle (ICC = 0.98; 95%CI: 0.96 to 0.99); and, functional flexion ratio at PT angle (ICC = 0.95; 95%CI: 0.89 to 0.98). Technical error of measurement (TEM) and associated percentage of the coefficient of variation (%CV) were as follows: conventional ratio at PT angle (TEM = 0.02; %CV = 4.1); functional extension ratio at PT angle (TEM = 0.02; %CV = 3.8); and, functional flexion ratio at PT angle (TEM = 0.03; %CV = 3.6). The current study demonstrated that the traditional and new obtained simple and combined isokinetic indicators seem highly reliable to assess muscle strength and function in adult male athletes. A single testing session seems to be sufficiently to obtain these isokinetic strength indicators.
URI: https://hdl.handle.net/10316/107983
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0202261
Direitos: openAccess
Aparece nas coleções:I&D IBILI - Artigos em Revistas Internacionais
FMUC Medicina - Artigos em Revistas Internacionais
I&D CIDAF - Artigos em Revistas Internacionais
FCDEF - Artigos em Revistas Internacionais

Mostrar registo em formato completo

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons