Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10316/107989
Título: | Reproducibility of estimated optimal peak output using a force-velocity test on a cycle ergometer | Autor: | Coelho-e-Silva, Manuel J. Gonçalves, Ricardo Rebelo Martinho, Diogo V. Ahmed, Alexis Marques Luz, Leonardo G. O. Duarte, João P. Severino, Vítor José Santos Baptista, Rafael Valente-dos-Santos, João Vaz, Vasco Gonçalves, Rui S. Tessitore, Antonio Fgueiredo, António J. |
Data: | 2018 | Editora: | Public Library of Science | Projeto: | uid/dtp/04213/2016 SFRH/BD/121441/2016 SFRH/BD/101083/ 2014 SFRH/BPD/100470/2014 SFRH/BD/72111/2010 |
Título da revista, periódico, livro ou evento: | PLoS ONE | Volume: | 13 | Número: | 2 | Resumo: | The current study aimed to examine the reproducibility of estimated peak power and estimated pedal velocity in a multi-trial 10-s all-out cycling test among adult athletes (n = 22; aged 23.50±4.73 years). Stature, sitting height and body mass were measured. Leg length was estimated as stature minus sitting height. Body volume was obtained from air displacement plethysmography and was subsequently used to calculate body density. Fat mass and fat-free mass were derived. The short-term power outputs were assessed from the force-velocity test (FVT), using a friction-braked ergometer on two separated occasions. Differences between repeated measurements were examined with paired t-test and effect sizes calculated. No significant differences were found between session 1 (898 W, 142 rpm) and session 2 (906 W, 142 rpm). Test-retest procedure showed acceptable reliability for estimated peak power output [technical error of measurement (TEM) = 31.9 W; % coefficient of variation (CV) = 3.5; intra-class correlation coefficient (ICC) = 0.986] and pedal velocity (TEM = 5.4 rpm, %CV = 3.8, ICC = 0.924). The current study demonstrated a reasonable reproducibility of estimated peak power and pedal velocity outputs in non-elite male athletes and supports that a familiarization session including a complete FVT protocol is not required. | URI: | https://hdl.handle.net/10316/107989 | ISSN: | 1932-6203 | DOI: | 10.1371/journal.pone.0193234 | Direitos: | openAccess |
Aparece nas coleções: | I&D CIDAF - Artigos em Revistas Internacionais FCDEF - Artigos em Revistas Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Reproducibility-of-estimated-optimal-peak-output-using-a-forcevelocity-test-on-a-cycle-ergometerPLoS-ONE.pdf | 843 kB | Adobe PDF | Ver/Abrir |
Visualizações de página
137
Visto em 2/out/2024
Downloads
28
Visto em 2/out/2024
Google ScholarTM
Verificar
Altmetric
Altmetric
Este registo está protegido por Licença Creative Commons