Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10316/27352
Título: | Development, optimization and application of an analytical methodology by ultra performance liquid chromatography–tandem mass spectrometry for determination of amanitins in urine and liver samples | Autor: | Leite, Marta Freitas, Andreia Azul, Anabela Marisa Barbosa, Jorge Costa, Saul Ramos, Fernando |
Palavras-chave: | Amanitin; Tilmicosin; Urine; Liver | Data: | 17-Out-2013 | Editora: | Elsevier | Citação: | LEITE, Marta [et. al] - Development, optimization and application of an analytical methodology by ultra performance liquid chromatography–tandem mass spectrometry for determination of amanitins in urine and liver samples. "Analytica Chimica Acta". ISSN 0003-2670. Vol. 799 (2013) p. 77-87 | Título da revista, periódico, livro ou evento: | Analytica Chimica Acta | Volume: | 799 | Resumo: | Amanitins, highly toxic cyclopeptides isolated from various Amanita species, are the most potent poisons accounting for the hazardous effects on intestinal epithelium cells and hepatocytes, and probably the sole cause of fatal human poisoning. The present study was focused on the development, optimization and application of an analytical methodology by ultra performance liquid chromatography-tandem mass spectrometry (UPLC–MS/MS), following urine and liver sample preparation by protein precipitation with organic solvents, and solid phase extraction (SPE) procedure, for the determination of the amatoxins, α- and β-amanitin. Linearity, detection and quantification limits, selectivity, sensitivity, intra and inter-assay precision and recovery were studied, in order to guarantee reliability in the analytical results. The developed method proved to be specific and selective, with LOD (Limit of Detection) values for α- and β-amanitin of 0.22 and 0.20 ng mL−1 in urine and 10.9 and 9.7 ng g−1 in liver, respectively. LOQ (Limit of Quantification) values ranged from 0.46 to 0.57 ng mL−1in urine and 12.3–14.7 ng g−1 in tissue, for both amanitins. Linearity, in the range of 10.0–200.0 ng mL−1or ng g−1, shows that coefficients of correlation were greater than 0.997 for α-amanitin and 0.993 for β-amanitin. Precision was checked at three levels during three consecutive days with intra-day and inter-day coefficients of variation not greater than 15.2%. The extraction recovery presents good results for the concentrations analyzed, with values ranging from 90.2 to 112.9% for both matrices. Thus, the proposed analytical method is innovative, presents a high potential in the identification, detection and determination of α- and β-amanitins in urine and tissue samples, as well as in other biological samples, such as kidney and mushrooms. | URI: | https://hdl.handle.net/10316/27352 | ISSN: | 0003-2670 | DOI: | 10.1016/j.aca.2013.08.044 | Direitos: | openAccess |
Aparece nas coleções: | FFUC- Artigos em Revistas Internacionais I&D CEFarmacêuticos - Artigos em Revistas Internacionais I&D CFE - Artigos em Revistas Internacionais FCTUC Ciências da Vida - Artigos em Revistas Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
DEVELOPMENT, OPTIMIZATION AND APPLICATION OF AN ANALYTICAL METHODOLOGY.pdf | 731.27 kB | Adobe PDF | Ver/Abrir |
Citações SCOPUSTM
31
Visto em 11/nov/2022
Citações WEB OF SCIENCETM
5
28
Visto em 2/mai/2023
Visualizações de página 20
766
Visto em 30/out/2024
Downloads 50
615
Visto em 30/out/2024
Google ScholarTM
Verificar
Altmetric
Altmetric
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.