Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/83860
Title: | Reprodutibilidade dos Momentos de Força dos Extensores e Flexores do Joelho por Dinamometria Isocinética: análise dos momentos máximos de força e dos índices convencionais e funcionais. | Other Titles: | Reproducibility pf knee extensors and flexors strength isokinetic moments: analysis of peak torque, conventional and functional ratios | Authors: | Couto, Pedro Rúben Gomes | Orientador: | Duarte, João Pedro Marques Silva, Manuel João Cerdeira Coelho |
Keywords: | força; erro técnico de medida; coeficiente de correlação intra-classe; fiabilidade; strength; technical error of measurement; intra-class correlation; reliability | Issue Date: | 21-Apr-2017 | metadata.degois.publication.title: | Reprodutibilidade dos Momentos de Força dos Extensores e Flexores do Joelho por Dinamometria Isocinética: análise dos momentos máximos de força e dos índices convencionais e funcionais. | metadata.degois.publication.location: | Coimbra | Abstract: | A prevenção de lesões através da deteção de desequilíbrios musculares regula-se por ratios Icon/Qcon. Com o acumular de horas de treino, os atletas tendem a estar expostos a um maior risco de ocorrência de desequilíbrios musculares e consequente diminuição da performance. Os desequilíbrios podem levar a que ocorram lesões quando o atleta realizar determinado movimento. A diferença de força e/ou défice de flexibilidade entre estruturas musculares provoca maior/menor tensão em determinados músculos e interrompem o bom funcionamento dos mesmos. O presente estudo objetiva: verificar a reprodutibilidade da produção de força muscular dos músculos extensores e flexores da articulação do joelho nas expressões momento de força máxima e ratios. A amostra compreende 32 alunos na área do treino desportivo, masculinos, (27.63 ± 10.08) que foram avaliados em dois momentos distintos para testar a reprodutibilidade do protocolo. Para a ação concêntrica, as medidas de força simples apresentaram valores “quase perfeitos”: MFMQ a 60°.s-1 (CCI=0,955; 95%CI: 0,880 to 0,968); MFMI a 60°.s-1 (CCI=0,916; 95%CI: 0,755 to 0,920); MFMQ a 180°.s-1 (CCI=0,922; 95%CI: 0,772 to 0,992); MFMI 180°.s-1 (CCI=0,780; 95%CI: 0,425 to 0,811); MFMQ a 300°.s-1 (CCI=0,900; 95%CI: 0,753 to 0,935); MFMI a 300°.s-1 (CCI=0,809; 95%CI: 0,394 to 0,871). Os valores compostos apresentaram uma reprodutibilidade “moderada”: I/Q ratio para 60°.s-1 (CCI=0,777; 95%CI: 0,341 to 0,781); I/Q ratio para 180°.s-1 (CCI=0,555; 95%CI: 0,108 to 0,746) e I/Q ratio para 300°.s-1 (CCI=0,652; 95%CI: 0,089 to 0,880). Os valores de reprodutibilidade dos MFM para as ações excêntricas são “moderados”: MFMQ a 60°.s-1 (CCI=0,738; 95%CI: 0,313 to 0,786); MFMI a 60°.s-1 (CCI=0,745; 95%CI: 0,342 to 0,773); MFMQ a 180°.s-1 (CCI=0,822; 95%CI: 0,513 to 0,832); MFMI a 180°.s-1 (CCI=0,797; 95%CI: 0,393 to 0,827). Uma vez mais os índices compostos apresentaram valores de reprodutibilidade inferiores: I/Q ratio para 60°.s-1 (CCI=0,655; 95%CI: 0,020 to 0,694) e ratio I/Q for 180°.s-1 (CCI=0,785; 95%CI: 0,111 to 0,685). Para as medidas simples ocorreu uma aceitável reprodutibilidade sendo que para as medidas compostas a reprodutibilidade apresentou valores mais modestos. The injury prevention through the detection of neuromuscular imbalances is regulated by H/Q ratios. With training hour’s accumulation, athletes tend to be exposed to a greater risk of muscular imbalances occurrence and consequent decrease in performance. Injuries can occur when exists a difference in strength and / or flexibility between muscular structures, and can cause greater / less tension in certain muscle groups and interrupt their proper functioning. The present study aims to verify the reproducibility of muscle strength production of knee muscle extensors and flexors in the expressions of maximum force moment and ratios. The total sample comprised 32 males’ master students (27.63 ± 10.08) in the branch of youth training, who were assessed in two independent moments to examine reliability of the protocol. For concentric actions all single measurements fluctuated from “substantial” to “almost perfect” reliable: Q peak torque at 60°.s-1 (ICC=0.955; 95%CI: 0.880 to 0.968); H peak torque at 60°.s-1 (ICC=0.916; 95%CI: 0.755 to 0.920); Q peak torque at 180°.s-1 (ICC=0.922; 95%CI: 0.772 to 0.992); H peak torque at 180°.s-1 (ICC=0.780; 95%CI: 0.425 to 0.811); Q peak torque at 300°.s-1 (ICC=0.900; 95%CI: 0.753 to 0.935); H peak torque at 300°.s-1 (ICC=0.809; 95%CI: 0.394 to 0.871). Composite scores reveal “moderate” reliability: H/Q ratio for 60°.s-1 (ICC=0.777; 95%CI: 0.341 to 0.781); H/Q ratio for 180°.s-1 (ICC=0.555; 95%CI: 0.108 to 0.746) and H/Q ratio for 300°.s-1 (ICC=0.652; 95%CI: 0.089 to 0.880). The peak outputs for eccentric single measurements are “moderate” reliable: Q peak torque at 60°.s-1 (ICC=0.738; 95%CI: 0.313 to 0.786); H peak torque at 60°.s-1 (ICC=0.745; 95%CI: 0.342 to 0.773); Q peak torque at 180°.s-1 (ICC=0.822; 95%CI: 0.513 to 0.832); H peak torque at 180°.s-1 (ICC=0.797; 95%CI: 0.393 to 0.827). Once again composite scores expose lower values for reliability: H/Q ratio for 60°.s-1 (ICC=0.655; 95%CI: 0.020 to 0.694) and H/Q ratio for 180°.s-1 (ICC=0.785; 95%CI: 0.111 to 0.685). Simple measurements showed an acceptable reproducibility, while composite scores presented more modest values. |
Description: | Dissertação de Mestrado em Treino Desportivo para Crianças e Jovens apresentada à Faculdade de Ciências do Desporto e Educação Física | URI: | https://hdl.handle.net/10316/83860 | Rights: | openAccess |
Appears in Collections: | UC - Dissertações de Mestrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Pedro Couto_Reproducibilidade_Final_2012148064_20170301.pdf | 1.43 MB | Adobe PDF | View/Open |
Page view(s) 50
650
checked on Nov 6, 2024
Download(s) 50
657
checked on Nov 6, 2024
Google ScholarTM
Check
This item is licensed under a Creative Commons License